2017.11.7
Followings are category per application for pressure gauge.
Application | Operational conditions | ||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
General |
1. Conditions at an installation
2. Installation position:Pressure gauges should be installed in vertical directions, dial and its indications should be in horizontal direction for the line of sight.3. Vibration and shock: The pointer must not be exceeded the specified pressure range of the tolerance of measurement accuracy.4. Pressure medium: Non-corrosive fluids or gasses (for non-corrosive performance should be used SUS316 for wetted parts.)5. Working pressure: The upper limit of normal working pressure range is specified in the table below.
Remark |
||||||||||||||||||||||||||||||
Steam |
1. The ambient Temp.: should be within 10 - 50°C, temporally becomes high temperature like steam at the start of operation.2. Other conditions: refer to Ordinary conditions 2, 3, 4 and 5.3. Symbol M: is displayed to indicate the heatproof type of use. |
||||||||||||||||||||||||||||||
Heatproof |
1. Maximum ambient Temp.: 80°C2. Other conditions: refer to Ordinary conditions 2, 3, 4 and 5.3. Symbol H: is displayed to indicate the heatproof type of use. |
||||||||||||||||||||||||||||||
Vibration-proof (for Intense vibration) |
1. Pulsation or vibration: the degree of pulsation or vibration that causes the pointer to shake beyond the accuracy tolerance, is specifically within the following range in the table below.[Pulsation range]After continuously applying pulsation pressure below 1Hz, there shall be no functual abnormality tithin the accuracy tolerance..
[Vibration range]Mount in normal posture and carry out the test in three directions, look for a resonance point with conditions given in table below and then excite for 2 hours and carry out the instrumental error test. When the resonance point cannot be found, apply the vibration of +/- 6.9m/s 30Hz in each of three directions for two hours or longer.
2. Other conditions: refer to Ordinary conditions 1, 2 4 and 5.3. Symbol V: is displayed to indicate the vibration-proof type of use. |
||||||||||||||||||||||||||||||
Steam/Vibration- proof |
1. Conditions: have the characteristics of both steam and vibration-proof.2. Symbol MV: is displayed to indicate the steam/vibration-proof type of use. |
||||||||||||||||||||||||||||||
Heat-/Vibration proof |
1. Conditions: have the characteristics of both heat and vibration-proof.2. Symbol HV: is displayed to indicate the steam/vibration-proof type of use. |
{ }: is a standard established by our company to improve performance and does not apply to JIS B 7505.
Pressure gauge, thermo sensors, thermometer,
and other related products.